2nd Ed. Oxley Press, 1975 - 447 p. Fundamentals of protection. Basic technology. Fault calulations. Equivalent circuits and parameters of power system plant. Current and voltage transformers. Electromagnetic relays. Static relays. Protection signalling. Overcurrent and earth fault protection. Unit protection of feeders. Distance protection. Carrier aided distance schemes. Protection of parallel and multi-ended feeders. Auto-reclosing. Busbar protection. Transformer and transformer-feeder protection. Generator and generator-transformer protection. Intertripping. A.C. motor protection. Rectifier protection. Testing and commissioning. Relay application tables.
Чтобы скачать этот файл зарегистрируйтесь и/или войдите на сайт используя форму сверху.
Technical Publications, 2006 - 395 p. ISBN 81-8431-019-6. Protective relaying. Electromagnetic relays. Differential protection. Distance protection. Generator protection. Induction motor protection. Transformer protection. Carrier aided protection and static relays. Theory of arc quenching. Circuit breakers. Power system earthing. Protection against overvoltage.
3rd edition - Taylor & Francis Group, LLC, 2006. - 638 p. ISBN 1-57444-716-5. This book presents the fundamentals and basic technology of application of protective relays in electric power systems and documents the protection practices in common use. The objective is to provide a useful reference for practicing engineers and technicians as well as a practical book for college...
We usually think of an electric power system in terms of its more impressive parts-the big
generating stations, transformers, high-voltage lines, etc. While these are some of the basic
elements, there are many other necessary and fascinating components. Protective relaying
is one of these.
Designs and Patents Act, 1988. - 508 p.
First published in Great Britain and the United States in 2006 by ISTE Ltd.
Apart from any fair dealing for the purposes of research or private study, or criticism or review, as permitted under the Copyright, Designs and Patents Act 1988. This publication may only be reproduced, stored or transmitted, in any form or by any means, with the...
356 p. Теория, практика и расчет линий электропередаи и электроснабжения. ABB Protection Application Handbook. Revision 0. Book No. 6. BU Transmissions systems and substations.
CRC Press Taylor & Francis Group, 2006. — 565 p. (OCR with errors).
Generator Normal Operations.
Generator Short Circuit Calculations.
Generator Differential Relay: 87G.
Backup Fault Protection.
Generator Ground Fault Protection.
Unbalanced Current Protection.
Motoring Protection.
Field Winding Protection.
Overexcitation.
Abnormal Frequency Protection.
Minimum...